Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 1-Pole 30A 24V for PH15NA04200GBAAA
Carrier

OEM Carrier Contactor 1-Pole 30A 24V for PH15NA04200GBAAA

SKU: CARRIE-PH15NA04200GBAAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH15NA04200GBAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single-Pole Contactor 30 Amp 24V Coil — HN51KC024 for Model PH15NA04200GBAAA

This is the factory-authorized OEM replacement contactor for the Carrier PH15NA04200GBAAA heat pump. The contactor is the high-voltage relay that bridges the thermostat's 24V control signal to the high-voltage compressor and condenser fan motor circuits. When your thermostat calls for cooling or heating, the 24V coil energizes and pulls in the contacts — allowing line voltage to power your compressor. When a contactor fails, symptoms include the outdoor unit not starting at all, humming without compressor engagement, contacts that weld shut causing continuous operation, or visible pitting and burn marks on the contact surfaces.

  • Specs: 1-Pole | 30A FLA (Full Load Amps) | 150A LRA (Locked Rotor Amps) | 24 VAC Coil | 50/60 Hz | OEM Part# HN51KC024
  • OEM vs Generic: This genuine Carrier Factory Authorized Part is manufactured to exact OEM tolerances. Generic contactors often use lower-grade contact materials that pit and weld faster under load — especially critical on heat pump systems like the PH15NA04200GBAAA that cycle frequently in both heating and cooling modes.
  • Install difficulty: 2/5 — Always disconnect power at the breaker and discharge any residual voltage before touching terminals. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor. Verify 24V coil pull-in after installation with a thermostat call.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PH15NA04200GBAAA. Also cross-references part numbers P282-0311, HN51CC024, P282-1304, and P282-1305. Confirm your unit's data plate lists HN51KC024 as the specified contactor before ordering. Our parts team is available to verify fitment — just reach out before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH15NA04200GBAAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH15NA04200GBAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH15NA04200GBAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online