OEM Carrier High & Low Pressure Switch Kit (312926-252 / 312926-258) for Model PH14NB06000GAAAA

These factory OEM pressure switches are the direct replacements for the Carrier PH14NB06000GAAAA packaged heat pump unit. The high pressure switch (312926-252, 670/470 PSI) monitors refrigerant discharge pressure and shuts down the compressor if pressure exceeds safe limits — protecting the system from catastrophic failure. The low pressure switch (312926-258, 55/23 PSI) guards against low-charge or loss-of-refrigerant conditions by cutting power to the compressor before damage occurs. Common failure symptoms include hard lockouts, nuisance tripping, or a unit that short-cycles and won't stay running. A failed pressure switch often triggers a fault code on the control board before any other component is tested.

  • Part Numbers: 312926-252 (High Pressure Switch, 670/470 PSI cutout/reset) | 312926-258 (Low Pressure Switch, 55/23 PSI cutout/reset) — both are genuine Carrier Factory Authorized Parts
  • OEM vs Generic: OEM switches are factory-calibrated to exact PSI setpoints for the PH14NB06000GAAAA refrigerant circuit. Generic alternatives may drift in calibration over time, causing nuisance trips or, worse, failing to protect the compressor under genuine fault conditions.
  • Install Difficulty: 3/5 — Refrigerant circuit work requires an EPA 608 certified technician. Tools needed: manifold gauge set, needle-nose pliers, wire crimper/stripper, multimeter. Always recover refrigerant before disconnecting any pressure-side fittings. Photograph wiring before removal.
  • Warranty: 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PH14NB06000GAAAA packaged heat pump. Verify your unit's data plate PSI ratings match 670/470# (high) and 55/23# (low) before ordering. Not sure? Our HVAC parts specialists verify fitment before you buy — contact us today. Order now and ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH14NB06000GAAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH14NB06000GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH14NB06000GAAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.