Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Condenser Unit Contactor Relay for PH14NB02400GAAAA
Carrier

OEM Carrier Condenser Unit Contactor Relay for PH14NB02400GAAAA

SKU: CARRIE-PH14NB02400GAAAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH14NB02400GAAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Condenser Unit Contactor Relay for PH14NB02400GAAAA

The contactor is the electrically operated power switch that feeds high-voltage line power to your Carrier PH14NB02400GAAAA condensing unit. When the thermostat calls for cooling, the 24-volt control circuit energizes the contactor coil, which pulls the contacts closed and energizes the compressor and outdoor fan motor. When the contactor fails, the classic symptom is an outdoor unit that stays silent while the indoor blower runs. Homeowners also describe a loud humming or buzzing from the condenser, rapid clicking or chatter, or — when the contacts weld together — a unit that runs continuously and won't shut off even after the thermostat is satisfied. Burned, pitted, or corroded contacts are among the most frequent causes of a no-cool breakdown. This is a definite-purpose contactor with a 24V control coil and silver-alloy contacts rated to the compressor's full-load amps (FLA) and locked-rotor amps (LRA). Match the pole configuration (single- or double-pole) and the contact amperage rating to the original part. OEM matters because genuine contacts use heavier silver-cadmium-oxide tips and a properly wound coil. Undersized aftermarket contacts arc and pit faster, increasing resistance and voltage drop that overheats the compressor windings and shortens compressor life. A weak generic coil may not fully close the contacts, causing chatter and damaging single-phasing. Install difficulty: 2 of 5. Tools: 1/4" and 5/16" nut drivers, an insulated screwdriver, a multimeter, and needle-nose pliers. Photograph the wiring before removal. Safety warning: shut off the outdoor disconnect AND the breaker first — line voltage is present at the terminals; confirm 0 volts with your meter before disconnecting any wires. Ships same business day from our stocked warehouse on orders before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH14NB02400GAAAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH14NB02400GAAAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH14NB02400GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH14NB02400GAAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online