Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High & Low Pressure Switch Kit 670-470# — PH14NA060000BAAA
Carrier

OEM Carrier High & Low Pressure Switch Kit 670-470# — PH14NA060000BAAA

SKU: CARRIE-PH14NA060000BAAA-PRESSURE_SWITCH-312926-252 Brand: Carrier
Guaranteed to fit PH14NA060000BAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch Kit for Model PH14NA060000BAAA (312926-252 & 312926-258)

These OEM refrigerant pressure switches are the factory-specified replacements for the Carrier PH14NA060000BAAA heat pump. The high pressure switch (312926-252, 670-470# cut-out/cut-in) protects the compressor from dangerously elevated refrigerant pressure, while the low pressure switch (312926-258, 55-23# cut-out/cut-in) guards against loss-of-charge and low-suction conditions. When either switch fails or trips on a fault, the system will lock out, short-cycle, or refuse to start — and fault codes will typically point to a refrigerant pressure or compressor protection error.

  • Specs — High Pressure Switch (312926-252): 670 PSI cut-out | 470 PSI cut-in | Normally closed | SPST | Factory-matched OEM tolerances for R-410A systems
  • Specs — Low Pressure Switch (312926-258): 55 PSI cut-out | 23 PSI cut-in | Normally closed | SPST | Prevents compressor damage from low refrigerant charge
  • OEM vs Generic: OEM Carrier pressure switches are calibrated to exact factory setpoints. Generic aftermarket switches routinely ship with ±10–15% pressure tolerances, risking nuisance trips or — worse — failing to protect the compressor at true fault conditions. Only OEM guarantees the setpoint your system was designed around.
  • Install difficulty: 3/5 — Refrigerant system work requires an EPA 608 certification. Recover refrigerant before accessing the refrigerant circuit. Tools needed: manifold gauge set, refrigerant recovery machine, torque wrench, and leak detector. Always verify system pressures after replacement and before restart.
  • Warranty: 1-year OEM manufacturer warranty. Ships same business day from our stocked warehouse.

Compatibility: Engineered as direct OEM replacements for Carrier PH14NA060000BAAA 14 SEER R-410A heat pump condensers. Confirm refrigerant type and pressure switch setpoints on your unit's data plate before ordering. Our technical team is available to verify fitment before you buy — order with confidence and get your system back online fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier High & Low Pressure Switch Kit 670-470# — PH14NA060000BAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier High & Low Pressure Switch Kit 670-470# — PH14NA060000BAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier High & Low Pressure Switch Kit 670-470# — PH14NA060000BAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.