OEM Carrier Low Pressure Switch 55-23# (312926-258) for Model PH14EB06000GABAB

This factory OEM low pressure switch (part number 312926-258) is the manufacturer-specified replacement for the Carrier PH14EB06000GABAB heat pump. The low pressure switch continuously monitors refrigerant pressure on the low side of the system. When pressure drops below the factory-set threshold of 55 PSI cut-out / 23 PSI cut-in, the switch opens the control circuit and shuts down the compressor — protecting it from running in a low-charge or restricted-flow condition. Common symptoms of a failed low pressure switch include the compressor refusing to start, the system locking out on a low pressure fault, or the unit short-cycling and failing to maintain setpoint temperature.

  • Specs: 55-23# (55 PSI cut-out / 23 PSI cut-in) | Factory OEM Sensata/PS80 series | Brass inlet connector | Precision-calibrated diaphragm | Pre-wired color-coded leads | Part No. 312926-258
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Part. OEM pressure switches are calibrated to exact factory cut-in/cut-out tolerances, ensuring reliable compressor protection. Off-brand substitutes may have wider pressure tolerances, leading to nuisance lockouts or — worse — insufficient compressor protection.
  • Install Difficulty: 2/5 — Always recover refrigerant and relieve system pressure before disconnecting the switch. Tools needed: manifold gauge set, adjustable wrench, needle-nose pliers, multimeter. Photograph wiring before disconnecting leads. EPA 608 certification required for refrigerant handling.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PH14EB06000GABAB heat pump. Always verify the part number on your existing switch and the refrigerant type on your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — reach out before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH14EB06000GABAB?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH14EB06000GABAB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH14EB06000GABAB?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.