Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA
OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA
OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA
OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA
Carrier

OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA

SKU: CARRIE-PH13PR06000GACAA-FAN_MOTOR-HC39GE237 Brand: Carrier
Guaranteed to fit PH13PR06000GACA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 208-230V for Model PH13PR06000GACAA

This is the factory-specified OEM condenser fan motor for the Carrier PH13PR06000GACAA heat pump condenser. The condenser fan motor draws ambient air across the outdoor condenser coils, dissipating the heat absorbed from your home and enabling the refrigerant cycle to repeat. When this motor fails, airflow stops — the compressor overheats, high-pressure safeties trip, and the system shuts down entirely. Common failure signs include: the outdoor unit humming but the fan blade not spinning, the system short-cycling on a high-pressure lockout, or the condenser fan blade spinning only when manually nudged (capacitor and motor both suspect). OEM part numbers covered by this listing: HC39GE237 (primary) and HC40GE232 (superseded/alternate).

  • Specs: 1/4 HP | 1100 RPM | 208-230V / 1-Phase / 60 Hz | 1.40 Amp | 48Y Frame | Rotation: CWLE (Clockwise Lead End) | Shaft: 1/2" diameter | Pre-installed mounting studs
  • OEM vs Generic: This is a genuine Carrier/GE factory motor wound to exact torque and thermal-protection specs. Aftermarket motors may differ in winding resistance and internal thermal cutout temperature, leading to nuisance trips or shortened compressor life. OEM is the only choice when protecting a system still under labor warranty.
  • Install Difficulty: 3/5 — Requires safely de-energizing the unit at the disconnect and confirming zero voltage with a multimeter. A fan-blade puller is strongly recommended to avoid bending the blade hub on removal. Tools needed: 5/16" and 1/4" nut drivers, needle-nose pliers, multimeter, torque wrench, fan-blade puller. Always photograph all wiring connections before disconnecting. Run capacitor should be tested (or replaced) at the same time.
  • Warranty & Shipping: 1-year OEM factory warranty against defects. In stock and ships same business day from our warehouse. Free ground shipping on orders over $99.

Compatibility: Direct OEM replacement for Carrier model PH13PR06000GACAA heat pump condensing units. Also cross-references HC39GE237A, HC40GE232, HC39GE236A, HC39GE234A, HC39GE232A, HC37GE232, HC39GE231, and GE Genteq 5KCP39FGS071S. Always verify HP, RPM, voltage, frame, and rotation direction against your unit's data plate before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my Carrier OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA?
Yes. This is the factory-specified OEM fan motor for the Carrier OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my Carrier OEM Carrier Condenser Fan Motor 1/4 HP 1100 RPM 230V — PH13PR06000GACA?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online