Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Condenser Fan Motor 1/4 HP 230V for PH13PR04800GAFAA
OEM Carrier Condenser Fan Motor 1/4 HP 230V for PH13PR04800GAFAA
OEM Carrier Condenser Fan Motor 1/4 HP 230V for PH13PR04800GAFAA
OEM Carrier Condenser Fan Motor 1/4 HP 230V for PH13PR04800GAFAA
Carrier

OEM Carrier Condenser Fan Motor 1/4 HP 230V for PH13PR04800GAFAA

SKU: CARRIE-PH13PR04800GAFAA-FAN_MOTOR-HC39GE237 Brand: Carrier
Guaranteed to fit PH13PR04800GAFAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Condenser Fan Motor 1/4 HP 208-230V 1100 RPM for Model PH13PR04800GAFAA

This is a genuine OEM Carrier condenser fan motor (part number HC39GE237) and is the factory-specified replacement for the Carrier PH13PR04800GAFAA heat pump condenser unit. The condenser fan motor drives the outdoor fan blade to pull air across the condenser coil, rejecting heat during cooling mode and absorbing heat during heating mode. When the motor fails, you'll typically notice the outdoor fan not spinning, the system short-cycling on high-pressure lockout, ice buildup on the coil, or the unit shutting down on thermal overload within minutes of starting. Also covers alternate OEM part number HC38GE231 where applicable — verify your unit's data plate before ordering.

  • Specs (HC39GE237): 1/4 HP | 208-230V | 1100 RPM | Frame 48Y (5-5/8" diameter) | Clockwise rotation (CW) | 3-wire | Shaft: 1/2" diameter × 1.5" extension | Replaces: HC39GE237A, HC39GE236A, HC39GE234A, HC39GE232A, HC37GE232, HC39GE231, 5KCP39FGS071S
  • OEM vs Generic: This is a genuine Carrier/GE Genteq OEM motor wound to exact factory tolerances — not a third-party substitute. OEM motors maintain proper airflow CFM, correct shaft geometry, and factory thermal protection thresholds, preventing nuisance trips and premature compressor failure caused by insufficient heat rejection.
  • Install Difficulty: 3/5 — Requires disconnecting line-voltage power at the disconnect box and discharging the run capacitor before touching any terminals. Tools needed: 5/16" and 3/8" nut driver, needle-nose pliers, multimeter, fan blade puller (highly recommended). Photograph all wiring before disconnecting. Note: Always inspect and replace the run capacitor when replacing the motor — a weak capacitor is a leading cause of repeat motor failure.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse. Free shipping on orders over $99.

Compatibility: Fits Carrier model PH13PR04800GAFAA heat pump condensers. This listing covers primary OEM part number HC39GE237 and also applies to cross-reference part HC38GE231 — always confirm horsepower, RPM, voltage, and rotation direction against your unit's data plate before installing. Questions about fitment? Our team verifies compatibility before you order — reach out before purchasing.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my Carrier PH13PR04800GAFAA?
Yes. This is the factory-specified OEM fan motor for the Carrier PH13PR04800GAFAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my Carrier PH13PR04800GAFAA?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online