This is the factory OEM low pressure switch for the Carrier PH13PR04200GAJAA heat pump. The low pressure switch continuously monitors refrigerant-side pressure in the system and trips open at 27 PSI to protect the compressor when suction pressure drops dangerously low — a condition caused by refrigerant loss, a restricted metering device, or a blocked filter. Without a functioning switch, a low-charge system will run unprotected, leading to compressor burnout. When this switch fails or trips, your system will typically short-cycle, throw a lockout fault code, or refuse to run the compressor entirely.
Compatibility: Designed for the Carrier PH13PR04200GAJAA heat pump. Verify your unit's existing switch PSI setpoints and lead length against your data plate before ordering. Not sure if this is the right part? Our HVAC parts specialists verify fitment before you buy — reach out before placing your order.