OEM Carrier High & Low Pressure Switch Kit for PH13PB06000GAAAA
Carrier

OEM Carrier High & Low Pressure Switch Kit for PH13PB06000GAAAA

SKU: CARRIE-PH13PB06000GAAAA-PRESSURE_SWITCH-312926-252 Brand: Carrier
Guaranteed to fit PH13PB06000GAAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch Kit (312926-252 / 312926-258) for Model PH13PB06000GAAAA

This OEM-matched pressure switch kit includes both the high pressure switch (312926-252, 670/470 PSI) and the low pressure switch (312926-258, 55/23 PSI) factory-specified for the Carrier PH13PB06000GAAAA packaged heat pump unit. Pressure switches are refrigerant-circuit safety controls: the high pressure switch trips when system pressure exceeds safe operating limits to protect the compressor from over-pressurization, while the low pressure switch opens on a loss-of-charge condition to prevent compressor damage from inadequate lubrication. A failed pressure switch typically causes nuisance lockouts, a system that starts then immediately shuts down, or a unit that refuses to enter the heating or cooling cycle at all.

  • Part Numbers & Specs: High Pressure Switch — OEM Part# 312926-252 | Set Point: 670 PSI cut-out / 470 PSI cut-in | Low Pressure Switch — OEM Part# 312926-258 | Set Point: 55 PSI cut-out / 23 PSI cut-in | Factory Authorized Parts (Carrier RCD)
  • OEM vs Generic: Genuine Carrier OEM pressure switches are factory-calibrated to exact set-point tolerances. Aftermarket substitutes often carry wider PSI tolerances, risking false trips or — more dangerously — failure to trip under a true fault condition, leaving your compressor unprotected.
  • Install Difficulty: 3/5 — Refrigerant circuit work must be performed by an EPA Section 608 certified technician. The system must be recovered before replacing refrigerant-side pressure switches. Tools required: manifold gauge set, recovery machine, refrigerant scale, multimeter, and 1/4" flare fitting tools. Always verify system pressure after recharge before returning the unit to service.
  • Warranty: 1-year OEM manufacturer warranty. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: This kit is designed for the Carrier PH13PB06000GAAAA packaged heat pump. Verify both part numbers against your unit's wiring diagram and data plate before ordering — high and low switches are not interchangeable. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you order. In stock — ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH13PB06000GAAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH13PB06000GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH13PB06000GAAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.