OEM Carrier Low Pressure Switch 55-23# (312926-258) for Model PH13PA04800GABAA

This is the factory OEM low pressure switch for the Carrier PH13PA04800GABAA heat pump. The low pressure switch continuously monitors refrigerant pressure on the low side of the system and opens the circuit to the compressor if pressure drops below the safe threshold — protecting the compressor from catastrophic damage caused by refrigerant loss or a restricted metering device. Common failure symptoms include the system locking out shortly after startup, the compressor refusing to energize, or a fault code indicating a low-pressure trip event at the thermostat or control board.

  • Specs: 55 PSI cut-out / 23 PSI cut-in | Factory-calibrated SPST normally-closed switch | Brass inlet connector with precision-calibrated diaphragm | Compact form factor — 2" H × 1" W × 0.5" D | Weight: 0.34 lbs
  • OEM vs Generic: Carrier OEM part 312926-258 is factory-set and factory-tested to exact cut-in/cut-out pressure tolerances. Aftermarket alternatives often carry wider pressure tolerances, risking nuisance trips or, worse, inadequate compressor protection.
  • Install Difficulty: 2/5 — Recover all refrigerant per EPA Section 608 regulations before replacing. Tools needed: manifold gauge set, refrigerant recovery machine, adjustable wrench, wire strippers. Pre-wired color-coded leads simplify reconnection. Always verify refrigerant charge after reinstallation.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Carrier PH13PA04800GABAA 4-ton 13 SEER heat pump. Verify your unit's data plate and existing switch markings match the 55-23# pressure rating before ordering. Our fitment team is available to confirm compatibility — call or chat before you order. Order now and ship today!

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH13PA04800GABAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH13PA04800GABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH13PA04800GABAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.