Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Single-Pole 40A Contactor for PH13NR060000ACAA Heat Pump
Carrier

OEM Carrier Single-Pole 40A Contactor for PH13NR060000ACAA Heat Pump

SKU: CARRIE-PH13NR060000ACAA-CONTACTOR-HN51JD026 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single-Pole Contactor for PH13NR060000ACAA Heat Pump

The contactor is the electrically operated switch that sends line voltage to your Carrier PH13NR060000ACAA heat pump's compressor and condenser fan motor every time the thermostat calls. When the 24V coil energizes, the contacts pull in and power the outdoor unit. When it fails — pitted, arced, or welded contacts — you'll notice the outdoor unit won't start, a loud chattering or humming buzz at the condenser, the fan spinning while the compressor stays silent, or a unit that won't shut off because the contacts have fused closed. This is a single-pole, 24VAC-coil definite-purpose contactor sized for the compressor and fan load of this 60,000 BTU (5-ton-class) unit, typically rated 30–40A FLA. Genuine silver-alloy contacts and a sealed coil resist the arc erosion that high compressor inrush current causes. OEM matters here because Carrier contactors use full-rated silver-cadmium contacts and a coil matched to the control circuit. Generic contactors often use undersized or thinly plated contacts that pit and arc faster under start-up inrush, causing voltage drop, chatter, and eventual weld-up that can lock the compressor on and cook the windings — the most expensive failure on the unit. Install difficulty: 2 of 5. Tools: 1/4" and 5/16" nut drivers, insulated screwdriver, multimeter, and a phone photo of the wiring before you disconnect anything. #1 safety warning: shut off the breaker and the outdoor disconnect, THEN discharge the run capacitor before touching any terminal — the capacitor holds a lethal charge even with power removed. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR060000ACAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH13NR060000ACAA Heat Pump?
Yes. This is the factory-specified OEM contactor for the Carrier PH13NR060000ACAA Heat Pump. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH13NR060000ACAA Heat Pump?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online