OEM Carrier Definite Purpose 40A Contactor for Model PH13NR04800GAEAA
Carrier

OEM Carrier Definite Purpose 40A Contactor for Model PH13NR04800GAEAA

SKU: CARRIE-PH13NR04800GAEAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH13NR04800GAEAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Definite Purpose Contactor for Model PH13NR04800GAEAA

The contactor acts as the main power gateway for your Carrier outdoor unit, switching high-voltage power to the compressor and condenser fan on command from the thermostat. A 24V control signal energizes its coil, snapping the contacts closed to deliver line voltage; when the call ends, the coil de-energizes and the contacts spring open. Over thousands of cycles those contacts pit and burn, and you'll notice the symptoms: a persistent humming or chattering at the outdoor unit, an air conditioner that clicks but won't start, or contacts welded closed that leave the system running continuously with no way to shut it off at the wall. This OEM contactor matches the pole count and electrical rating your equipment requires: a 24VAC coil and contacts rated for roughly 30–40A full load, engineered to handle the high inrush surge of a starting compressor. Confirm single- vs. double-pole configuration, coil voltage, and amperage against the part you're pulling. Why OEM matters here: the difference is in the contact metallurgy and coil. Cheap aftermarket contactors use thinner, lower-grade contacts and weaker coils that arc, pit, and weld much sooner under repeated compressor inrush — a false economy that often fails within a single cooling season. The OEM part is rated for your unit's actual surge load so it lasts. Install difficulty: 2 of 5. Tools needed: a 1/4" nut driver, needle-nose pliers, and a multimeter, plus a wiring photo or labels before disconnecting anything. SAFETY: turn off the breaker and pull the disconnect, then discharge the run capacitor in the same compartment before touching wiring — line voltage and capacitor charge can both shock you. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR04800GAEAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier Model PH13NR04800GAEAA?
Yes. This is the factory-specified OEM contactor for the Carrier Model PH13NR04800GAEAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier Model PH13NR04800GAEAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online