Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Definite Purpose 40A Contactor for Model PH13NR048000AFAA
Carrier

OEM Carrier Definite Purpose 40A Contactor for Model PH13NR048000AFAA

SKU: CARRIE-PH13NR048000AFAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH13NR048000AFAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Definite Purpose Contactor for Model PH13NR048000AFAA

The contactor is the high-current switch at the heart of your Carrier condenser's electrical system. When your thermostat calls for cooling, it sends a 24V signal that energizes the contactor coil, drawing the contacts together to feed full line voltage to the compressor and condenser fan motor. Each cooling cycle wears those contacts a little more, and eventually you'll see the warning signs: a loud hum or buzz from the outdoor cabinet, an air conditioner that won't kick on, or contacts that have arc-welded shut so the unit runs non-stop and ignores the thermostat. Ants and dirt wedged in the contact gap are a frequent cause of failure on these units. This OEM contactor is built to your unit's specifications: a 24VAC coil with contacts rated for approximately 30–40A full load and sized for HVAC compressor inrush current. Check the pole count (single or double pole), coil voltage, and amp rating against the contactor you're removing. Why OEM matters here: a contactor is only as good as its contacts and coil. Generic aftermarket units routinely cut costs with undersized, lower-grade contacts and weaker coils that pit, arc, and weld far sooner under the repeated surge of a starting compressor — often failing again within a season. The OEM contactor is engineered for your equipment's true inrush load. Install difficulty: 2 of 5, among the easiest HVAC fixes. Tools: a 1/4" nut driver, needle-nose pliers, and a multimeter, plus a photo of the wiring before you disconnect. SAFETY: shut off the breaker and disconnect, then discharge the run capacitor in the same compartment before handling any wires — both carry a serious shock hazard. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR048000AFAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier Model PH13NR048000AFAA?
Yes. This is the factory-specified OEM contactor for the Carrier Model PH13NR048000AFAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier Model PH13NR048000AFAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online