OEM Carrier Definite Purpose Contactor for PH13NR04200GAFAA Heat Pump

The contactor is the high-current relay that switches line voltage to the compressor and condenser fan motor in your Carrier PH13NR04200GAFAA heat pump. When the thermostat calls, the 24-volt control circuit energizes the contactor coil, the contacts snap closed, and the outdoor unit powers up. It is a high-wear part — it makes and breaks under load thousands of times a season — so worn contacts and failed coils are among the most frequent no-cool and no-heat service calls. Watch for the outdoor unit staying silent while the indoor blower runs, a steady hum or buzzing chatter at the condenser, short-cycling, or contacts welded shut that keep the compressor energized until the breaker trips. This is a definite-purpose contactor matched to the PH13 platform's compressor and fan load. Replace it with the same pole configuration (single- or double-pole), the same 24V coil, and an equal-or-greater contact amperage rating (commonly 30–40 FLA / 40 amp resistive) stamped on the old part. The coil voltage must match or the contactor won't pull in. Why OEM matters: genuine Carrier contactors use full-size silver-alloy contacts and a properly tensioned coil and spring. Bargain aftermarket units cut corners with thinner contacts that pit, arc, and overheat — raising resistance and eventually welding closed, a failure mode that can take the compressor down with it. Installation difficulty: 2 of 5. Tools: 1/4" and 5/16" nut drivers, needle-nose pliers, a multimeter, and a photo of the wiring before you start. SAFETY: shut off the breaker and pull the outdoor disconnect before touching the contactor — line voltage is present at the terminals even with the thermostat off. Confirm zero volts with your meter first. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR04200GAFAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH13NR04200GAFAA Heat Pump?
Yes. This is the factory-specified OEM contactor for the Carrier PH13NR04200GAFAA Heat Pump. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH13NR04200GAFAA Heat Pump?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.