Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Single-Pole Contactor for PH13NR03000GAHAA Heat Pump
Carrier

OEM Carrier Single-Pole Contactor for PH13NR03000GAHAA Heat Pump

SKU: CARRIE-PH13NR03000GAHAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single-Pole Contactor for PH13NR03000GAHAA Heat Pump

The contactor is the high-voltage switch that connects line power to your Carrier heat pump's compressor and condenser fan. When the thermostat calls, the 24V coil pulls the contacts closed and the unit roars to life. Over time the silver contacts pit, burn, and weld — symptoms a homeowner notices as a loud hum or buzz from the outdoor unit, a fan that runs while the compressor stays dead, a unit that won't shut off (welded contacts), or chattering and short-cycling as the coil weakens. This genuine Carrier contactor carries the correct coil voltage (24V) and contact amperage rating for the PH13NR compressor load, with heavy silver-alloy contacts and the factory pole configuration, terminal layout, and mounting bracket sized for this cabinet. Why OEM matters here: aftermarket contactors frequently use undersized contacts that pit and arc faster, dropping voltage to the compressor and shortening its life. A genuine contactor's full-rated silver contacts handle locked-rotor inrush without burning, protecting your most expensive component. Install difficulty: 2 of 5. Tools needed: 1/4" and 5/16" nut driver, needle-nose pliers, multimeter, and a phone photo of the wiring before you start. SAFETY: shut off the breaker AND pull the outdoor disconnect, then verify zero volts across the line terminals with your meter — the load side stays energized even with the thermostat off. Move one wire at a time to the new contactor. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR03000GAHAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH13NR03000GAHAA Heat Pump?
Yes. This is the factory-specified OEM contactor for the Carrier PH13NR03000GAHAA Heat Pump. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH13NR03000GAHAA Heat Pump?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online