Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Definite Purpose Contactor for Heat Pump PH13NR02400GAHAA
Carrier

OEM Carrier Definite Purpose Contactor for Heat Pump PH13NR02400GAHAA

SKU: CARRIE-PH13NR02400GAHAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH13NR02400GAHAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Definite Purpose Contactor for Heat Pump PH13NR02400GAHAA

The contactor is the high-voltage switch that energizes your Carrier heat pump's compressor and condenser fan motor whenever the thermostat calls for cooling or heat-pump heating. A 24-volt signal from the control board pulls in the contactor coil, closing the line-voltage contacts that feed 240V to the outdoor unit. When a contactor fails, you'll hear a loud humming or chattering at the outdoor unit, the fan and compressor may refuse to start, the breaker can trip, or the system runs nonstop because welded contacts won't release. Burnt, pitted, or insect-fouled contacts are one of the most common no-cool service calls. This genuine OEM definite-purpose contactor matches the factory coil voltage (24V), contact rating (typically 30–40A), and pole configuration for the PH13NR cabinet, so it drops straight onto the existing mounting bracket and wiring. Definite-purpose contactors are sized for the locked-rotor inrush of an HVAC compressor — not a generic relay rating. Why OEM matters: aftermarket contactors frequently use undersized or thinner silver-alloy contacts that pit and weld faster under repeated inrush, leading to stuck-closed failures that run the compressor without thermostat control and shorten its life. OEM contact mass and coil specs are matched to your unit's draw. Install difficulty: 2 of 5. Tools: 1/4" and 5/16" nut drivers, insulated screwdriver, and a multimeter to confirm coil continuity. #1 safety warning: SHUT OFF the 240V disconnect and the indoor breaker before touching any wiring — the line-side terminals stay live even with the thermostat off. Photograph the wires before removal. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR02400GAHAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier Heat Pump PH13NR02400GAHAA?
Yes. This is the factory-specified OEM contactor for the Carrier Heat Pump PH13NR02400GAHAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier Heat Pump PH13NR02400GAHAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online