OEM Carrier Contactor for PH13NR024000AFAA Heat Pump Condenser

The contactor is the high-voltage switch that powers your Carrier PH13NR heat pump's compressor and outdoor fan. When your thermostat calls for heating or cooling, a 24V signal energizes the contactor coil, pulling the contacts closed to send 240V line power to the unit. It's one of the hardest-working parts in the system, slamming closed and open every cycle all season. When a contactor fails you'll see the classic symptoms: the outdoor unit won't start (no hum, no fan), it buzzes loudly, the contacts chatter, or — the dangerous one — the contacts weld shut and the compressor runs nonstop even with the thermostat off, freezing the indoor coil. This OEM Carrier contactor is rated for the correct coil voltage (24V) and contact amperage (commonly 30A, single- or double-pole to match your unit) with silver-alloy contacts sized for the compressor's locked-rotor inrush current. Verify pole count and coil voltage against your old part. Why OEM matters: contactors live or die by contact quality. Generic units use undersized or lower-grade contacts that pit and arc faster under heavy inrush load, leading to voltage drop, overheating, and premature compressor wear. An OEM contactor's properly sized contacts resist welding and deliver clean, full voltage cycle after cycle. Install difficulty: 2/5. Tools: 1/4" nut driver, needle-nose pliers, multimeter, and a photo of the wiring before removal. #1 safety warning: kill the breaker to the outdoor unit AND discharge the run capacitor before working — line voltage at the contactor terminals will shock you even with the thermostat off. Ships same business day from our stocked warehouse on orders before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NR024000AFAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH13NR024000AFAA Heat Pump Condenser?
Yes. This is the factory-specified OEM contactor for the Carrier PH13NR024000AFAA Heat Pump Condenser. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH13NR024000AFAA Heat Pump Condenser?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online