Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Heat Pump Condenser Contactor for PH13NB06000GAAAA
Carrier

OEM Carrier Heat Pump Condenser Contactor for PH13NB06000GAAAA

SKU: CARRIE-PH13NB06000GAAAA-CONTACTOR-HN51JD026 Brand: Carrier
Guaranteed to fit PH13NB06000GAAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Heat Pump Condenser Contactor for PH13NB06000GAAAA

The contactor is the high-current switch that powers your Carrier PH13NB06000GAAAA heat pump's compressor and outdoor fan. When the thermostat calls, a 24V signal energizes the contactor coil, pulling the contacts closed to deliver line voltage to the condenser. It's one of the most-cycled parts in the unit, and as the contacts wear the symptoms are unmistakable: a loud buzzing or humming at the outdoor unit, the fan and compressor failing to start, chatter as the contacts make and break, or a unit that runs continuously because pitted contacts have welded shut. This is a genuine OEM contactor sized for the PH13 platform — correct coil voltage (24VAC), the original pole configuration, and a contact and amp rating matched to the compressor's locked-rotor and run current. Mounting footprint and terminal layout match the factory bracket and harness. Generic contactors frequently use undersized silver-content contacts and thinner coil windings. Under the inductive inrush of an HVAC compressor those contacts pit, arc, and weld far faster, leading to repeat failures and, in the worst case, a compressor that can't drop out. Matching the OEM contact rating is what keeps the switch — and the compressor it protects — alive. Install difficulty: 2 of 5 (one of the easier outdoor-unit repairs). Tools: 1/4" nut driver, Phillips screwdriver, multimeter, and a photo of the wiring before you start. SAFETY: kill the breaker AND pull the outdoor disconnect before touching the contactor — line voltage is present on the load side even with the thermostat off, and the nearby run capacitor can hold a lethal charge. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NB06000GAAAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH13NB06000GAAAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH13NB06000GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH13NB06000GAAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online