Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Defrost Control Board HK32EA007 — PH13NB024000AAAA
Carrier

OEM Carrier Defrost Control Board HK32EA007 — PH13NB024000AAAA

SKU: CARRIE-PH13NB024000AAAA-CONTROL_BOARD-HK32EA007 Brand: Carrier
Guaranteed to fit PH13NB024000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Defrost Control Board HK32EA007 for Model PH13NB024000AAAA

This is the genuine OEM Carrier defrost control board (part number HK32EA007), the factory-specified replacement for the Carrier PH13NB024000AAAA heat pump. The defrost control board manages the automatic defrost cycle — monitoring outdoor coil temperature and initiating timed defrost sequences to remove frost and ice buildup from the evaporator coil. When this board fails, common symptoms include a heat pump that never enters defrost mode (leading to a heavily iced outdoor unit), a system that gets stuck in defrost and blows cold air indoors, or a unit that short-cycles and shuts down on fault lockout. Replacing the board with a genuine OEM part restores factory-programmed defrost timing and temperature logic.

  • Part Number: HK32EA007 | Also cross-references: 1177927, 1173636 | OEM Carrier / Bryant / Payne heat pump defrost board
  • OEM vs Generic: This is a 100% genuine Carrier OEM board — not an aftermarket clone. OEM boards retain factory defrost timing intervals and termination thresholds, which aftermarket boards may approximate but rarely replicate exactly, risking premature coil icing or compressor stress.
  • Install Difficulty: 3/5 — Requires shutting off power at both the breaker and disconnect before accessing the control compartment. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, phone camera to photograph wiring harness positions before disconnecting. Transfer wiring connections one at a time to avoid errors. Recheck all low-voltage thermostat wire terminals after installation.
  • Warranty: 1-year OEM manufacturer warranty from date of purchase. Ships same business day from our warehouse when ordered by 3 PM local time.

Compatibility: Engineered as the direct factory replacement for Carrier model PH13NB024000AAAA split-system heat pumps. This board also cross-applies to select Bryant and Payne heat pump platforms sharing the same control architecture. Always verify your existing board's part number against HK32EA007 before ordering. Our parts specialists are available to confirm fitment — contact us before you buy if you have any questions. Order today and get same-day shipping.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Defrost Control Board HK32EA007 — PH13NB024000AAAA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Defrost Control Board HK32EA007 — PH13NB024000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Defrost Control Board HK32EA007 — PH13NB024000AAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart