Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor for PH13NB024000AAAA Condenser Heat Pump
Carrier

OEM Carrier Contactor for PH13NB024000AAAA Condenser Heat Pump

SKU: CARRIE-PH13NB024000AAAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor for PH13NB024000AAAA Condenser Heat Pump

The contactor is the electrically operated switch that delivers high-voltage power to the compressor and condenser fan motor whenever the thermostat calls. A 24V signal from the control circuit energizes the contactor coil, pulling the contacts closed to pass 208/230V to the outdoor unit on your PH13NB024000AAAA. When it fails you'll hear a loud buzzing or chattering at the outdoor unit, find the system dead with no startup, or — if the contacts weld shut — a unit that runs nonstop and won't shut off even when satisfied. Pitted, burned, or arc-damaged contacts are the single most common cause of an outdoor unit that simply won't come on. This is a definite-purpose contactor with a 24V coil, available as 1-pole or 2-pole, typically rated 30 or 40 FLA at 600V. Match the pole count, coil voltage (24V), and amp rating to your original, and confirm the mounting footprint and terminal layout. Genuine Carrier contactors use silver-alloy contacts and a coil sized to this unit's inrush load. Generic contactors frequently use undersized or lower-grade contacts that pit and arc faster, leading to chatter, voltage drop, and premature compressor wear. A correctly rated OEM contactor delivers clean, full voltage on every cycle and lasts far longer under real inrush conditions. Install difficulty: 2 of 5. Tools: 1/4" nut driver, needle-nose pliers, and a multimeter to verify coil and contact continuity. Safety: kill the breaker and pull the outdoor disconnect, then discharge the run capacitor before touching any wiring — the contactor sits right beside line-voltage terminals. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NB024000AAAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH13NB024000AAAA Condenser Heat Pump?
Yes. This is the factory-specified OEM contactor for the Carrier PH13NB024000AAAA Condenser Heat Pump. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH13NB024000AAAA Condenser Heat Pump?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.