Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Defrost Control Board HK32EA007 — PH13NAZ30000AAAA
Carrier

OEM Carrier Defrost Control Board HK32EA007 — PH13NAZ30000AAAA

SKU: CARRIE-PH13NAZ30000AAAA-CONTROL_BOARD-HK32EA007 Brand: Carrier
Guaranteed to fit PH13NAZ30000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Defrost Control Board HK32EA007 for Model PH13NAZ30000AAAA

This is the factory OEM Defrost Control Board (part number HK32EA007) for the Carrier PH13NAZ30000AAAA heat pump. The defrost control board manages the automatic defrost cycle, monitoring outdoor coil temperature and initiating timed defrost sequences to melt frost and ice accumulation off the evaporator coil. When this board fails, you'll typically see the outdoor unit ice over completely, the system short-cycling, loss of heating capacity in cold weather, or the heat pump stuck in defrost mode and unable to switch back to heating operation.

  • Specs: OEM Part No. HK32EA007 | Replaces cross-references 1173636 & 1177927 | Factory-matched timing intervals and sensor logic | Compatible with 24V control circuit
  • OEM vs Generic: This OEM board uses factory-calibrated defrost timing and termination logic. Aftermarket boards frequently use generic timing intervals that cause premature or delayed defrost cycles, reducing efficiency and accelerating compressor wear.
  • Install difficulty: 3/5 — Disconnect power at the breaker before beginning. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, phone/camera to photograph existing wiring harness connections before removal. Transfer connectors one at a time to avoid miswiring.
  • Warranty: 1-year OEM manufacturer warranty. In-stock units ship same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PH13NAZ30000AAAA heat pump. This board also cross-references Carrier/Bryant/Payne platforms sharing the HK32EA007 specification. Always verify your existing board's part number against the unit's data plate before ordering. Have a fitment question? Our HVAC parts team confirms compatibility before you buy — call or chat today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Defrost Control Board HK32EA007 — PH13NAZ30000AAAA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Defrost Control Board HK32EA007 — PH13NAZ30000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Defrost Control Board HK32EA007 — PH13NAZ30000AAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.