Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Heat Pump Pressure Switch Assembly for PH13NA036000ABAA
Carrier

OEM Carrier Heat Pump Pressure Switch Assembly for PH13NA036000ABAA

SKU: CARRIE-PH13NA036000ABAA-PRESSURE_SWITCH-312926-252 Brand: Carrier
Guaranteed to fit PH13NA036000ABAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Heat Pump Pressure Switch Assembly for PH13NA036000ABAA

The pressure switch on your Carrier PH13NA036000ABAA Performance 13 heat pump is a refrigerant-side safety control that constantly monitors system pressure and cuts power to the compressor before damaging high- or low-pressure conditions can develop. It guards against loss of charge, a blocked condenser coil, restricted airflow, or a failing metering device. When this switch goes bad or sticks open, the most common symptom is short-cycling — the unit starts, runs for a few seconds or minutes, then shuts off. You may also notice the outdoor unit refusing to start at all, no heating or cooling reaching the registers, or the system locking out on a fault after several failed attempts. A nuisance-tripping switch is often mistaken for a refrigerant or compressor problem, so verifying it first prevents an expensive misdiagnosis. This is a SPST pressure-actuated switch (normally closed for low-pressure protection, normally open for high-pressure cut-out) with factory-calibrated cut-out and cut-in setpoints matched to R-410A operating pressures. OEM switches hold those setpoints within Carrier's tested PSI tolerance, so they trip exactly when protection is needed and reset cleanly afterward. Why OEM matters here: a generic switch with the wrong cut-out PSI or a wider tolerance band will either trip too early (constant nuisance lockouts) or too late (letting the compressor run under damaging pressure). The wrong switch can cost you a compressor — far more than the price difference. OEM guarantees the exact setpoint and electrical rating for this unit. Install difficulty: 2/5. Tools: 1/4" and 5/16" nut driver, adjustable wrench, and a multimeter for continuity testing. #1 safety warning: shut off the breaker to the outdoor unit before disconnecting any wiring, and never bypass a pressure switch to force the unit to run. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH13NA036000ABAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH13NA036000ABAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH13NA036000ABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH13NA036000ABAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.