OEM Carrier High & Low Pressure Switch Kit (312926-252 & 312926-258) for Model PH13NA02400GABAA

These are the factory OEM replacement pressure switches for the Carrier PH13NA02400GABAA heat pump. The high pressure switch (312926-252, rated 670-470 PSI) monitors refrigerant discharge pressure and shuts the compressor down before dangerously high pressure can cause mechanical failure. The low pressure switch (312926-258, rated 55-23 PSI) guards the compressor against operating in a low-charge or restricted-airflow condition. Together, these two switches form the primary refrigerant-circuit safety net for your system. When either switch fails or trips without reset, you'll typically see a compressor lockout fault code, short-cycling, or a unit that runs the indoor blower but never engages the outdoor compressor.

  • Specs — High Pressure Switch (312926-252): 670 PSI cut-out / 470 PSI cut-in | Refrigerant-side protection | Factory Authorized Part | Replaces: 312926252
  • Specs — Low Pressure Switch (312926-258): 55 PSI cut-out / 23 PSI cut-in | Compressor loss-of-charge protection | Factory Authorized Part | Replaces: 312926258
  • OEM vs Generic: OEM switches are factory-calibrated to exact cut-in/cut-out thresholds. Generic alternatives frequently carry ±10–15% pressure tolerances, risking nuisance trips or, worse, insufficient compressor protection that voids equipment warranties.
  • Install difficulty: 3/5 — Refrigerant-side work requires an EPA 608 certification. Tools needed: manifold gauge set, refrigerant recovery unit, adjustable wrench, multimeter. Always recover refrigerant before disconnecting any pressure switch. Photograph all wire connections before removal.
  • Warranty: 1-year OEM manufacturer warranty on both switches. Ships same business day from our warehouse.

Compatibility: Direct OEM fit for Carrier model PH13NA02400GABAA (2-ton, single-stage R-410A heat pump). Verify refrigerant type and cut-out pressure ratings on your unit's data plate before ordering. Not sure if this is the right part? Our HVAC parts specialists verify fitment before you buy — contact us before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH13NA02400GABAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH13NA02400GABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH13NA02400GABAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.