Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Single-Pole Contactor Relay for PH12NA04200GABAA
Carrier

OEM Carrier Single-Pole Contactor Relay for PH12NA04200GABAA

SKU: CARRIE-PH12NA04200GABAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH12NA04200GABAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single-Pole Contactor Relay for PH12NA04200GABAA

The contactor is the heavy-duty electrical switch that delivers line voltage to the compressor and outdoor fan motor in your Carrier PH12NA04200GABAA condensing unit. Each time the thermostat calls for cooling, the 24-volt control circuit energizes the contactor's magnetic coil, snapping the contacts closed to power the unit. When a contactor fails, the symptoms are hard to miss: a loud buzzing or chattering hum at the outdoor unit, the fan spinning while the compressor never starts, repeated short-cycling, a tripped breaker, or contacts that weld shut so the system keeps running even after the thermostat is satisfied. Burnt or pitted contacts and a dead coil are the most common failure points. This is a single-pole, 30-amp contactor with a 24V AC coil, sized to handle the locked-rotor and full-load amperage of the compressor in this model. Silver-cadmium-oxide contacts and a sealed coil provide reliable pull-in across thousands of switching cycles. Genuine OEM contactors use heavier-gauge, silver-alloy contacts and properly rated coils. Cheap aftermarket units often ship with undersized contacts that pit and arc faster, leading to nuisance buzzing, voltage drop, and eventual compressor strain. Matching the OEM amp and coil rating protects the most expensive component in your system. Install difficulty: 2/5. Tools: 1/4" and 5/16" nut drivers, insulated needle-nose pliers, and a multimeter to confirm coil continuity and contact closure. #1 safety warning: shut off the outdoor disconnect and the breaker before touching anything — line voltage is present at the contactor terminals even when the thermostat is off. Photograph the wiring before removal. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH12NA04200GABAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH12NA04200GABAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH12NA04200GABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH12NA04200GABAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online