OEM Carrier Dual 35+5 MFD Run Capacitor Replacement for PH12NA036000ABAA

SKU: CARRIE-PH12NA036000ABAA-CAPACITOR-P291-5073RS Brand: Carrier
Guaranteed to fit PH12NA036000ABAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Run Capacitor Replacement for PH12NA036000ABAA

The dual run capacitor stores and releases electrical energy to keep your compressor and condenser fan motor running smoothly and efficiently, providing the steady phase shift both motors need to maintain torque. When it weakens or fails, you'll notice the outdoor fan not spinning (or needing a push to start), a humming compressor that won't start and trips on overload, warm air from the vents, hard starting, higher electric bills, and short-cycling. A bulged or domed top on the capacitor can is a dead giveaway. This is a dual round run capacitor matched to the PH12NA036000ABAA. Typical values are around 35/5 MFD (compressor/fan), rated 440 VAC, 50/60 Hz, with the OEM ±5% tolerance and rated for 10,000-plus hours of outdoor service. The HERM terminal feeds the compressor, FAN feeds the condenser motor, and C is common to line. Confirm both MFD values, voltage, and tolerance against the failed part. Capacitance tolerance matters more here than almost anywhere. OEM caps hold ±5%; many generic aftermarket capacitors drift to ±10–15%, and the wrong MFD starves the compressor of starting torque, stressing the windings, raising amp draw, and shortening compressor life. A genuine 440V-rated, tight-tolerance cap also survives outdoor heat far longer than a 370V budget unit. Install difficulty: 2/5 (easy, with one critical safety step). Tools needed: 1/4" nut driver, a multimeter with a capacitance setting, and an insulated screwdriver. SAFETY: a capacitor holds a lethal charge even after power is off — kill the breaker AND discharge the capacitor across a 20k-ohm resistor before touching the terminals. Photograph the HERM/FAN/C wiring first. Ships same business day from our stocked warehouse on orders before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH12NA036000ABAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Carrier PH12NA036000ABAA?
Yes. This is the factory-specified OEM capacitor for the Carrier PH12NA036000ABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Carrier PH12NA036000ABAA?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.