OEM Carrier Dual 40+5 MFD Run Capacitor for PH12NA030000ACAA Heat Pump
Carrier

OEM Carrier Dual 40+5 MFD Run Capacitor for PH12NA030000ACAA Heat Pump

SKU: CARRIE-PH12NA030000ACAA-CAPACITOR-P291-4573RS Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Run Capacitor for PH12NA030000ACAA Heat Pump

The run capacitor gives the compressor and condenser fan motor in your Carrier PH12NA030000ACAA the phase shift they need to start and run efficiently. It's a dual capacitor — one section for the compressor (HERM) and one for the fan (FAN) — storing and releasing energy on every cycle. When a capacitor weakens, you'll hear the compressor or fan humming but struggling to start, notice the outdoor fan spinning slowly or only after a push, see the breaker trip, or get warm air and short-cycling. A bulged, domed, or leaking can top is a dead giveaway. This is a dual run capacitor; verify the printed rating on your old can before ordering — common Carrier values are around 40+5 MFD at 440VAC, but the exact microfarad and voltage are stamped on the original. OEM capacitors are built to a tight ±5% tolerance and rated for continuous 440V duty at high ambient temperatures. Why OEM matters here: capacitance is everything for a cap. Generic units often carry a loose ±10–15% tolerance, so a cap that reads in spec on day one can drift out of range fast. The wrong MFD stresses the compressor start and run windings, drawing extra amperage, running hot, and shortening the life of the most expensive part in the system. Correct MFD and a true 440V rating protect the compressor. Install difficulty: 2 of 5. Tools: 1/4" nut driver, needle-nose pliers, an insulated screwdriver, and a multimeter with a capacitance test. #1 safety warning: a capacitor holds a dangerous charge even with power off — discharge it across the terminals with an insulated screwdriver or resistor before disconnecting any wires, and photograph the HERM/FAN/C wiring first. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH12NA030000ACAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Carrier PH12NA030000ACAA Heat Pump?
Yes. This is the factory-specified OEM capacitor for the Carrier PH12NA030000ACAA Heat Pump. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Carrier PH12NA030000ACAA Heat Pump?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.