OEM Carrier Dual Pressure Switch 0.80/1.70
Carrier

OEM Carrier Dual Pressure Switch 0.80/1.70" W.C. — PG9YAB036080AAAA

SKU: CARRIE-PG9YAB036080AAAA-PRESSURE_SWITCH-HK06NA016 Brand: Carrier
Guaranteed to fit PG9YAB036080AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch 0.80/1.70" W.C. for Model PG9YAB036080AAAA

This OEM dual pressure switch assembly (part # HK06NA016) is the factory-specified replacement for the Carrier PG9YAB036080AAAA 2-stage gas furnace. The pressure switch is a critical safety component designed to prove that the draft inducer motor is spinning at the correct RPM and generating sufficient negative pressure before allowing the furnace to proceed through the ignition sequence. When this switch fails or sticks open, the inducer will run continuously but the burners will never fire — leaving you with a furnace stuck in a safety lockout with no heat. This assembly includes two individual switches mounted on a factory bracket, covering both the low-stage (0.80" W.C.) and high-stage (1.70" W.C.) proving circuits required by the 2-stage combustion design.

  • Specs: Dual-switch assembly | Stage 1: –0.80" W.C. | Stage 2: –1.70" W.C. | Mounted on Honeywell 27555BM-01 bracket | Honeywell cross-reference: BA20238 | OEM part number: HK06NA016 (superseded by HK06MB025)
  • OEM vs Generic: This is a genuine OEM-spec assembly with factory-calibrated switching points. Aftermarket substitutes frequently use imprecise trip points that cause nuisance lockouts or, worse, fail to detect a true flue blockage — a serious safety risk on any gas furnace.
  • Install difficulty: 2/5 — Power and gas must be off before starting. Tools needed: flat-head screwdriver, needle-nose pliers. Photograph hose and wiring routing before disconnecting. Remove bracket as a complete assembly; swap hoses and wires one at a time to avoid miswiring the stage-1 and stage-2 circuits.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PG9YAB036080AAAA 2-stage gas furnace, and cross-references to additional Carrier, Bryant, and Payne 80% 2-stage furnace models. Always verify the W.C. ratings on your existing switch label before ordering. Have a fitment question? Our HVAC parts specialists confirm compatibility before you buy — order today and get it shipped the same day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch 0.80/1.70" W.C. — PG9YAB036080AAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch 0.80/1.70" W.C. — PG9YAB036080AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch 0.80/1.70" W.C. — PG9YAB036080AAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online