OEM Carrier Furnace Transformer 120V/24V 40VA for Model PG9YAA060100ABSS

This OEM control transformer (part number HT01BC117) is the factory-specified replacement for the Carrier PG9YAA060100ABSS gas furnace. The transformer steps down 120V line voltage to 24V AC, powering the entire low-voltage control circuit — including the thermostat, gas valve, inducer relay, and control board. When this transformer fails, the furnace goes completely unresponsive: the thermostat shows no call being answered, the board has no power, and the system will not attempt ignition. A failed transformer is often misdiagnosed as a bad control board, making accurate diagnosis critical before ordering.

  • Specs: 120V primary | 24V secondary | 40VA rating | Foot-mounted / chassis mount | OEM part number HT01BC117 (also crosses to HT01BC117A, BE161840GDD)
  • OEM vs Generic: This is a genuine OEM-spec transformer matched to Carrier factory tolerances. Generic 40VA transformers often run at the edge of their rated VA, causing nuisance tripping of the internal thermal fuse under normal furnace load — especially in systems with zone valves or humidifiers drawing additional VA.
  • Install difficulty: 2/5 — Disconnect power at the breaker and verify with a multimeter before servicing. Label and photograph all 24V secondary wiring before removal. Tools needed: flathead and Phillips screwdrivers, nut driver, multimeter. Transformer is foot-mounted and typically secured with two screws inside the furnace cabinet.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG9YAA060100ABSS gas furnace. Cross-references include HT01BC117A and Basler Electric BE161840GDD. Always verify primary voltage (120V), secondary voltage (24V), and VA rating (40VA) against your unit's data plate before ordering. Need help confirming fitment? Our HVAC parts specialists verify compatibility before every order — no guesswork.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier PG9YAA060100ABSS?
Yes. This is the factory-specified OEM transformer for the Carrier PG9YAA060100ABSS. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier PG9YAA060100ABSS?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.