Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Dual Pressure Switch Assembly for PG9YAA060100ABSS
Carrier

OEM Carrier Dual Pressure Switch Assembly for PG9YAA060100ABSS

SKU: CARRIE-PG9YAA060100ABSS-PRESSURE_SWITCH-HK06NA015 Brand: Carrier
Guaranteed to fit PG9YAA060100ABSS — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NA015 for Model PG9YAA060100ABSS

This OEM Dual Pressure Switch Assembly (part number HK06NA015) is the factory-specified replacement for the Carrier PG9YAA060100ABSS gas furnace. The dual pressure switch monitors negative pressure created by the draft inducer blower at both high-fire and low-fire stages — confirming that safe venting conditions exist before allowing the gas valve to open. When either switch fails or goes out of calibration, the furnace control board detects an open pressure switch circuit and locks out the ignition sequence entirely, leaving you with a no-heat call and a fault code pointing to inducer or pressure switch failure.

  • Specs: Dual-stage pressure switch assembly | Monitors both high-fire and low-fire inducer draft | Factory-calibrated W.C. setpoints | SPST normally-open configuration | Direct OEM replacement for Carrier P/N HK06NA015
  • OEM vs Generic: This OEM assembly ships with factory-matched W.C. trip points critical for two-stage furnace operation. Aftermarket dual switches often deviate in setpoint accuracy, causing nuisance lockouts or — worse — unsafe ignition under marginal venting conditions.
  • Install Difficulty: 3/5 — Requires disconnecting inducer hose ports, labeling and removing spade-terminal wiring, and confirming hose integrity before reinstallation. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, manometer (recommended to verify inducer static pressure after install). Always cycle power off at the breaker before beginning work.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before the daily cutoff.

Compatibility: Engineered for the Carrier PG9YAA060100ABSS two-stage gas furnace. Always cross-reference the W.C. rating printed on your existing switch against your unit's data plate before ordering — dual assemblies are stage-specific. Have questions about fitment? Our HVAC parts specialists verify compatibility before you buy. Order now — in stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG9YAA060100ABSS?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG9YAA060100ABSS. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG9YAA060100ABSS?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online