OEM Carrier Dual Pressure Switch 2-Stage for PG9UAA060100AASA
Carrier

OEM Carrier Dual Pressure Switch 2-Stage for PG9UAA060100AASA

SKU: CARRIE-PG9UAA060100AASA-PRESSURE_SWITCH-HK06NB023 Brand: Carrier
Guaranteed to fit PG9UAA060100AASA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB023 for Model PG9UAA060100AASA

This OEM dual pressure switch assembly is the factory-specified replacement for the Carrier PG9UAA060100AASA two-stage gas furnace. The pressure switch monitors negative pressure (draft) generated by the inducer motor to confirm safe combustion venting before allowing the gas valve to open. On a two-stage furnace like the PG9UAA060100AASA, a dual pressure switch monitors both the low-fire (Stage 1) and high-fire (Stage 2) inducer pressure levels independently. When it fails, the furnace will lock out before ignition — often flashing a fault code for "pressure switch stuck open" — leaving you with no heat.

  • Specs: Dual pressure switch assembly | Stage 1: –0.81" W.C. | Stage 2: –1.60" W.C. (min) / –1.81" W.C. (max) | Replaces OEM part numbers HK06NB023, HK06MB023, 319893-401, 319893-402, 325381-401
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact W.C. ratings for your specific inducer and heat exchanger configuration. Off-spec generic switches can trip prematurely or fail to prove draft, leading to repeated lockouts and potential heat exchanger stress.
  • Install difficulty: 2/5 — Power down the furnace and disconnect the hose(s) from the old switch. Label wires before removing. Tools needed: flat-head screwdriver, needle-nose pliers, and a manometer (optional, for verification). Typical job time: 15–30 minutes.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG9UAA060100AASA two-stage 96% AFUE gas furnace. Also fits select Bryant and Payne units sharing the same platform — verify your model's W.C. rating on the data plate before ordering. Our fitment team is available to confirm compatibility before you buy. Order today and receive fast, same-day shipping.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG9UAA060100AASA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG9UAA060100AASA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG9UAA060100AASA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.