Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Hot Surface Igniter Silicon Nitride — PG9MTAV60125ABSS
Carrier

OEM Carrier Hot Surface Igniter Silicon Nitride — PG9MTAV60125ABSS

SKU: CARRIE-PG9MTAV60125ABSS-IGNITER-LH33ZG002 Brand: Carrier
Guaranteed to fit PG9MTAV60125ABSS — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Silicon Nitride Hot Surface Igniter LH33ZG002 for Model PG9MTAV60125ABSS

This genuine OEM hot surface igniter (part number LH33ZG002) is the factory-specified replacement for the Carrier PG9MTAV60125ABSS gas furnace. The igniter is the critical component that glows to ignition temperature and lights the gas burners on each heating cycle. When it fails — either through a crack in the element or loss of continuity — the furnace control board detects no flame establishment and locks out after one or two ignition attempts, leaving you with a no-heat call. The silicon nitride construction on this OEM igniter offers superior durability over legacy silicon carbide designs, with greater resistance to thermal shock and a longer service life.

  • Part Type: Hot Surface Igniter (HSI) | Silicon Nitride element | OEM part number LH33ZG002 | Cross-reference: 1172533
  • OEM vs Generic: This is a genuine Carrier OEM igniter — not a universal aftermarket substitute. OEM igniters are matched to the exact wattage, geometry, and mounting bracket of the PG9MTAV60125ABSS, ensuring correct element temperature and reliable light-off every cycle. Generic universal kits may require bracket modification and often operate at mismatched wattages, leading to premature burnout or nuisance lockouts.
  • Install Difficulty: 2/5 — Always disconnect power and allow the furnace to cool before servicing. Do not touch the nitride element with bare hands — skin oils accelerate cracking. Tools needed: 1/4" nut driver, flat-blade screwdriver, multimeter (to verify open circuit on failed igniter). Typical replacement time: 20–30 minutes.
  • Warranty & Shipping: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before cutoff. Carefully packaged to prevent element damage in transit.

Compatibility: Engineered for the Carrier PG9MTAV60125ABSS gas furnace. Confirm your existing igniter part number on the element body or your unit's wiring diagram before ordering. If you are unsure of fitment, our team verifies compatibility before you buy — just reach out. Order now and restore heat today — same-day shipping available.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Carrier OEM Carrier Hot Surface Igniter Silicon Nitride — PG9MTAV60125ABSS?
Yes. This is the factory-specified OEM igniter for the Carrier OEM Carrier Hot Surface Igniter Silicon Nitride — PG9MTAV60125ABSS. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Carrier OEM Carrier Hot Surface Igniter Silicon Nitride — PG9MTAV60125ABSS?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online