Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor for PG9MAB060100ACSA Gas Furnace Rod
Carrier

OEM Carrier Flame Sensor for PG9MAB060100ACSA Gas Furnace Rod

SKU: CARRIE-PG9MAB060100ACSA-FLAME_SENSOR-LH680013 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor for PG9MAB060100ACSA Gas Furnace Rod

The flame sensor is the single metal rod that sits directly in the burner flame and proves to the control board that ignition actually happened. Through flame rectification it converts the burning gas into a tiny DC microamp signal. As the rod accumulates oxide or carbon, or simply ages, that signal falls below the board's minimum and the board closes the gas valve as a safety response. On the PG9MAB060100ACSA this shows up as short-cycling: the burners light, hold for only a few seconds, then shut off, the inducer purges, and the furnace retries until it locks out and quits making heat. This is a single-rod rectification sensor with a high-temperature stainless/Kanthal alloy tip and a ceramic insulator. A healthy rod produces about 1-6 microamps DC, and most Carrier boards require a stable minimum near 0.5-1.5 µA to keep the valve energized. The rod length and bend are set so the flame fully surrounds the tip. OEM matters because the rod's geometry and alloy are matched to this burner. Generic sensors with the wrong length, bend, or a cheaper tip sit partially outside the flame and put out a weak, erratic signal, triggering nuisance lockouts that get misdiagnosed as a bad board or valve. Install difficulty: 2 of 5. Tools: 1/4" nut driver, fine emery cloth or steel wool for adjacent contacts, and a multimeter that reads DC microamps to confirm the new signal. #1 safety warning: shut off the gas and kill power at the breaker before reaching into the burner compartment. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PG9MAB060100ACSA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PG9MAB060100ACSA Gas Furnace Rod?
Yes. This is the factory-specified OEM flame sensor for the Carrier PG9MAB060100ACSA Gas Furnace Rod. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PG9MAB060100ACSA Gas Furnace Rod?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online