Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Control Board for PG9MAB060100ACSA Module
Carrier

OEM Carrier Furnace Control Board for PG9MAB060100ACSA Module

SKU: CARRIE-PG9MAB060100ACSA-CONTROL_BOARD-HK42FZ013 Brand: Carrier
Guaranteed to fit Module — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Furnace Control Board for PG9MAB060100ACSA Module

The integrated furnace control (IFC) board is the brain of the PG9MAB060100ACSA. It runs the entire ignition sequence and times every component: it energizes the inducer, monitors the pressure switch, fires the igniter, opens the gas valve, watches the flame-sensing microamp signal, and stages the main blower on and off with the correct heat and cool delays. When it fails, the furnace may do nothing at all, run the inducer but never ignite, drop out mid-cycle, chatter its relays, or throw a flashing diagnostic fault code. Some homeowners also report a faint burnt-electronics smell or scorched relay terminals. This board carries an onboard 24VAC control circuit and typically four to six relays driving the inducer, the heat and cool blower taps, and the EAC/HUM accessory terminals, plus a microprocessor and a diagnostic LED that blinks fault codes. Compatibility is strict: it must be matched to the Carrier/Bryant control part number (the HK42FZ-series family) called out for this furnace, since firmware and timing are model-specific. OEM matters because the blower-off delay, soft-start logic, and flame-rectification thresholds are calibrated to this exact furnace. Generic or rebuilt boards can mis-time the blower, letting the heat exchanger overheat, or sense flame poorly and cause lockouts. Install difficulty: 3 of 5. Tools: 1/4" nut driver, a multimeter, and your phone to photograph the wiring before you touch it. #1 safety warning: kill the breaker and verify 0 volts before removing any wires — line voltage is present on this board — and label every connection. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PG9MAB060100ACSA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG9MAB060100ACSA Module?
Yes. This is the factory-specified OEM control board for the Carrier PG9MAB060100ACSA Module. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG9MAB060100ACSA Module?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online