OEM Carrier Pressure Switch with Bracket (HK06NB124) for Model PG9MAB060080LBSA

This OEM pressure switch with bracket is the factory-authorized replacement part for the Carrier PG9MAB060080LBSA gas furnace. The inducer pressure switch monitors negative pressure produced by the draft inducer motor to confirm proper venting before allowing ignition to proceed. When the diaphragm fails or the switch sticks, the furnace will fault before ever reaching ignition — leaving you with no heat and a blinking error code. Common symptoms include the inducer running continuously with no ignition, or an immediate lockout at startup.

  • Specs: 1.81" WC rating | -1.65" WC set point | SPST (Single-Pole, Single-Throw) | Normally Open | Includes factory mounting bracket | Manufactured by Honeywell for Carrier
  • OEM vs Generic: This is the OEM Carrier-authorized part (HK06NB124), precision-calibrated to factory tolerances. Generic switches often drift from rated set points, causing nuisance lockouts or — worse — allowing ignition under unsafe vent conditions. OEM is the only safe choice for pressure switches.
  • Install difficulty: 2/5 — Power down the furnace and confirm inducer is off before beginning. Tools needed: 1/4" nut driver, flathead screwdriver, needle-nose pliers. Note port orientation: the + and - ports are labeled, and one port contains an internal flow restrictor — match to the original before reconnecting hoses. Photograph wiring and hose routing before removal.
  • Warranty & Shipping: 1-year OEM manufacturer warranty against defects. In stock — ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PG9MAB060080LBSA gas furnace. Also supersedes obsolete part numbers HK06NB119, HK06NB120, and HK06NB122. Verify your existing switch's water column rating and port configuration before installation. Need help confirming fitment? Our HVAC parts team verifies compatibility before you order — just ask.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB060080LBSA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB060080LBSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB060080LBSA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online