Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB060080AASA
Carrier

OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB060080AASA

SKU: CARRIE-PG9MAB060080AASA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAB060080AASA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket HK06NB124 for Model PG9MAB060080AASA

This is the factory OEM replacement pressure switch with mounting bracket for the Carrier PG9MAB060080AASA gas furnace. The pressure switch is a critical safety device that monitors the negative pressure produced by the inducer motor to confirm proper venting before allowing the ignition sequence to proceed. When the switch fails or its diaphragm weakens, the control board cannot verify that the inducer is operating correctly, resulting in a hard lockout, a flashing fault code, or a furnace that attempts ignition but shuts down immediately — leaving you with no heat.

  • Specs: SPST (Single-Pole, Single-Throw) | Set point: -1.65" W.C. | 1.81" WC rated | Includes factory mounting bracket | Replaces obsolete part numbers HK06NB119, HK06NB120, HK06NB122
  • OEM vs Generic: This is the genuine Carrier OEM part — factory-calibrated to the exact pressure set point required by your PG9MAB060080AASA furnace. Aftermarket pressure switches often carry ±10–15% tolerance on the set point, which can result in nuisance lockouts or, worse, failure to detect a true venting fault — a safety risk.
  • Install difficulty: 2/5 — Shut off power and gas to the furnace before beginning. Disconnect the two low-voltage spade terminals (note: terminals are different sizes to prevent miswiring) and the rubber hose(s) from the switch ports. Photograph all connections before removal. Use a flathead screwdriver and needle-nose pliers. Tip: inspect hoses for cracks or blockages before installing the new switch.
  • Warranty: 1-year OEM factory warranty. In-stock — ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PG9MAB060080AASA gas furnace. This part supersedes HK06NB119, HK06NB120, and HK06NB122, all of which are now obsolete. Verify your existing switch's W.C. rating on the data plate before ordering. Need help confirming fitment? Our HVAC parts specialists are standing by — order now and we'll ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB060080AASA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB060080AASA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB060080AASA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online