Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB036060LBSA
Carrier

OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB036060LBSA

SKU: CARRIE-PG9MAB036060LBSA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAB036060LBSA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket (HK06NB124) for Model PG9MAB036060LBSA

This is the factory OEM replacement pressure switch with integrated mounting bracket for the Carrier PG9MAB036060LBSA gas furnace. The pressure switch monitors negative pressure created by the draft inducer motor to confirm safe combustion airflow before the control board allows the ignition sequence to proceed. When this switch fails or sticks open, the furnace will lock out on a pressure fault — typically before any ignition attempt — leaving you with a no-heat call and a flashing fault code. Replacing it with the correct OEM part restores factory-calibrated safety logic.

  • Specs: SPST (Single-Pole, Single-Throw) | 1.81" W.C. set point | Includes factory mounting bracket | Replaces superseded part numbers HK06NB120, HK06NB119, HK06NB122, and HK06ZB104
  • OEM vs Generic: OEM pressure switches are factory-calibrated to the exact W.C. rating required by your furnace's control board. Off-spec generic switches can trip too early or too late, causing nuisance lockouts or — worse — masking a real venting problem. Don't compromise on a safety component.
  • Install difficulty: 2/5 — Power down the furnace at the disconnect and thermostat before starting. Tools needed: 1/4" nut driver, flat-head screwdriver, needle-nose pliers. Photograph all hose connections before removal. Match the port labeled with a restrictor orifice on the old switch to the same port on the new switch before reattaching hoses.
  • Warranty: 1-year OEM factory warranty. Ships same business day from NationalHVACParts.com when ordered before cutoff.

Compatibility: Designed for the Carrier PG9MAB036060LBSA gas furnace. HK06NB124 is also the current superseding replacement used across more than 200 Carrier and Bryant residential furnace models — always verify the W.C. rating on your unit's data plate before installing. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you order — contact us today and get your part shipped out fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB036060LBSA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB036060LBSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAB036060LBSA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online