Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Control Board HK42FZ013 for PG9MAB036060ACSA
Carrier

OEM Carrier Furnace Control Board HK42FZ013 for PG9MAB036060ACSA

SKU: CARRIE-PG9MAB036060ACSA-CONTROL_BOARD-HK42FZ013 Brand: Carrier
Guaranteed to fit PG9MAB036060ACSA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Furnace Control Board HK42FZ013 for Model PG9MAB036060ACSA

The Carrier HK42FZ013 is the factory integrated furnace control (IFC) board for the PG9MAB036060ACSA gas furnace. As the brain of the heating system, this microprocessor-based board orchestrates every operating sequence — from inducer pre-purge and hot surface ignition through gas valve timing, blower motor staging, and post-purge shutdown. When this board fails, symptoms typically include a complete no-heat lockout, an ignition sequence that starts but aborts, erratic blower behavior, or a furnace that trips the pressure switch circuit before firing. The board's onboard diagnostic LED provides fault codes that help narrow down whether the issue is the board itself or a downstream component.

  • Specs: Input range 98–132 VAC at 60 Hz | Ignitor output: 5A at 120 VAC | Cool blower: 30A, 2 HP, 240 VAC | Heat blower: 5A, 1/2 HP, 240 VAC | Inducer motor: 4A at 120 VAC | Compatible with 24 VAC standard thermostat | OEM part number: HK42FZ013 | Cross-reference: CEPL130438-01, CEBD430438
  • OEM vs Generic: This is the genuine Carrier OEM board, factory-programmed with exact ignition trial timing (5-second trial, 3 retries) and blower delay profiles matched to the PG9MAB036060ACSA heat exchanger. Generic aftermarket boards may use broader timing tolerances that can stress the heat exchanger or result in nuisance lockouts over time.
  • Install difficulty: 3/5 — Requires disconnecting 24V low-voltage wiring harness, line-voltage blower and inducer leads, and gas valve terminals. Always photograph all connector positions before removal. Tools needed: #2 Phillips screwdriver, 1/4" nut driver, needle-nose pliers, and a multimeter to verify 24VAC signal before condemning the board. Discharge any capacitors and shut off power at the disconnect before starting.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Ships same business day from our stocked warehouse.

Compatibility: Direct OEM replacement for Carrier model PG9MAB036060ACSA gas furnace. Also cross-references CEPL130438-01 and CEBD430438 board assemblies. Verify your existing board's part number label before ordering — if your board shows an HK42FZ0XX suffix, contact our team for fitment confirmation. Questions about compatibility? Our HVAC parts specialists verify fitment before you order — reach out via chat or phone for same-day assistance.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG9MAB036060ACSA?
Yes. This is the factory-specified OEM control board for the Carrier PG9MAB036060ACSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG9MAB036060ACSA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.