Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket -1.65
Carrier

OEM Carrier Pressure Switch w/ Bracket -1.65" WC — PG9MAB036060AASA

SKU: CARRIE-PG9MAB036060AASA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAB036060AASA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket -1.65" WC for Model PG9MAB036060AASA

This is the factory-specified OEM pressure switch with mounting bracket for the Carrier PG9MAB036060AASA gas furnace. The pressure switch monitors negative pressure created by the induced draft blower to verify proper venting before allowing ignition to proceed. When this switch fails or becomes stuck, the furnace control board detects an unsafe condition and locks out the ignition sequence — leaving you with no heat and typically a fault code 31 or similar inducer-related error on the control board.

  • Specs: -1.65" W.C. set point | SPST (Single-Pole, Single-Throw) | Includes OEM mounting bracket | Supersedes HK06NB119, HK06NB120, HK06NB122
  • OEM vs Generic: This is the genuine Carrier OEM part — factory-calibrated to the exact W.C. set point required by the PG9MAB036060AASA heat exchanger and inducer assembly. Off-brand pressure switches with loose tolerances can cause nuisance lockouts or, worse, unsafe operation if the switch trips too late.
  • Install difficulty: 2/5 — The mounting bracket makes alignment straightforward. Tools needed: flathead screwdriver, 1/4" nut driver, needle-nose pliers. Photograph all hose connections before removal. Always verify inducer motor function and hose integrity before condemning the switch — a cracked hose is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG9MAB036060AASA gas furnace. Also fits over 200 Carrier and Bryant residential furnace models that share the HK06NB124 specification — verify the W.C. rating on your original switch before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket -1.65" WC — PG9MAB036060AASA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket -1.65" WC — PG9MAB036060AASA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket -1.65" WC — PG9MAB036060AASA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.