Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Control Board HK42FZ013 for PG9MAB036040ACSA
Carrier

OEM Carrier Furnace Control Board HK42FZ013 for PG9MAB036040ACSA

SKU: CARRIE-PG9MAB036040ACSA-CONTROL_BOARD-HK42FZ013 Brand: Carrier
Guaranteed to fit PG9MAB036040ACSA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Integrated Furnace Control Board HK42FZ013 for Model PG9MAB036040ACSA

This OEM Carrier integrated furnace control board (IFC) is the factory-specified replacement for the Carrier PG9MAB036040ACSA gas furnace. The control board is the brain of your furnace — it sequences every critical operation including inducer startup, hot surface ignition, gas valve timing, blower motor staging, and system fault monitoring. When this board fails, you may experience a furnace that won't heat, trips into hard lockout after ignition attempts, runs the inducer but never fires, or shows erratic blower behavior. Diagnostic LED fault codes on the board itself help pinpoint the failure before and after replacement.

  • OEM Part Number: HK42FZ013 | Cross-reference: CEPL130438-01, CEBD430438 | Factory board for Carrier PG9MAB036040ACSA
  • Key Specs: Single-stage HSI (hot surface ignition) control | 24 VAC thermostat compatible | Ignitor output: 5A at 120 VAC | Cool blower: 30A, 2 HP, 240 VAC | Heat blower: 5A, 1/2 HP, 240 VAC | Inducer motor: 4A at 120 VAC | Input range: 98–132 VAC at 60 Hz | Microprocessor-based with 100% gas shutoff on ignition failure
  • OEM vs Generic: This is a genuine OEM Carrier board — factory-programmed with exact timing sequences, safety thresholds, and blower delay profiles matched to the PG9MAB036040ACSA. Generic and aftermarket boards require wiring harness adapters and may not replicate OEM fault logic, potentially shortening heat exchanger life.
  • Install Difficulty: 3/5 — Requires powering down the furnace and discharging any stored voltage before handling. Tools needed: Phillips and flathead screwdrivers, needle-nose pliers, smartphone (photograph all wiring before disconnecting). ESD precaution strongly recommended — touch bare metal chassis before handling the board. Estimated time: 30–60 minutes for an experienced DIYer.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PG9MAB036040ACSA gas furnace. Also cross-references CEPL130438-01 and CEBD430438 board variants. Always verify your existing board's part number against the data label inside the furnace cabinet before ordering. Our team is available to confirm fitment — reach out before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG9MAB036040ACSA?
Yes. This is the factory-specified OEM control board for the Carrier PG9MAB036040ACSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG9MAB036040ACSA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online