OEM Carrier Pressure Switch w/ Bracket 1.81
Carrier

OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB036040ABSA

SKU: CARRIE-PG9MAB036040ABSA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAB036040ABSA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket (HK06NB124) for Model PG9MAB036040ABSA

This is the OEM factory-specified pressure switch with mounting bracket for the Carrier PG9MAB036040ABSA gas furnace. The pressure switch is a safety device that monitors the negative pressure created by the inducer motor — it must confirm that the inducer is running and the flue path is clear before allowing the ignition sequence to proceed. When it fails, the furnace will typically lock out before the igniter ever fires, often triggering a pressure switch fault code (commonly displayed as Error Code 31 on compatible Carrier and Bryant models).

  • Specs: 1.81" W.C. (water column) set point | SPST (Single-Pole, Single-Throw) | Normally Open | Includes factory mounting bracket | Honeywell-manufactured OEM component
  • OEM vs Generic: This OEM part is factory-calibrated to the exact pressure rating required by the PG9MAB036040ABSA. Aftermarket switches frequently drift in W.C. set point, causing nuisance lockouts or — worse — masking a true venting problem. The OEM switch also includes the correct bracket for a direct bolt-in fit.
  • Install difficulty: 2/5 — Turn off power and gas before servicing. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, a phone camera to photograph tubing and wiring positions. Match the hose ports (+/−) carefully — one port contains a factory flow restrictor/orifice that must be oriented correctly.
  • Warranty: 1-year OEM manufacturer warranty against defects. Ships same business day from our warehouse when ordered before cutoff.

Compatibility & Supersession: Fits Carrier model PG9MAB036040ABSA and is compatible across 200+ Carrier and Bryant residential furnace models. HK06NB124 is the current superseding part for obsolete part numbers HK06NB119, HK06NB120, HK06NB122, HK06NB123, and HK06ZB104. Verify your existing part number or furnace data plate before ordering — our team is available to confirm fitment. In stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB036040ABSA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB036040ABSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB036040ABSA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online