This is the factory OEM replacement pressure switch with bracket for the Carrier PG9MAB024060LBSA gas furnace. The pressure switch monitors negative pressure created by the inducer motor to confirm proper draft before allowing the ignition sequence to proceed. When this switch fails, your furnace will lock out before ignition — typically displaying an error code indicating a pressure switch fault — leaving you with no heat. A failed inducer motor, cracked hose, or blocked condensate drain can also trigger this switch, so always inspect those components before replacing.
Compatibility: Direct OEM replacement for Carrier PG9MAB024060LBSA gas furnaces. This part is also used across 200+ Carrier and Bryant residential furnace models — verify your model's data plate and existing pressure switch W.C. rating before ordering. Our parts specialists are available to confirm fitment prior to purchase. Order now and get it shipped today!