Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket -1.65
Carrier

OEM Carrier Pressure Switch w/ Bracket -1.65" WC for PG9MAB024060ABSA

SKU: CARRIE-PG9MAB024060ABSA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAB024060ABSA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket (HK06NB124) for Model PG9MAB024060ABSA

This OEM pressure switch with mounting bracket is the factory-specified replacement for the Carrier PG9MAB024060ABSA gas furnace. The pressure switch proves that the inducer blower has generated adequate negative pressure before the control board allows the ignition sequence to proceed. When the diaphragm weakens or the switch contacts fail, the furnace will lock out before ignition — typically displaying a pressure switch fault code — and no heat will be produced. A failed switch is one of the most common furnace no-heat diagnoses.

  • Specs: SPST (Single-Pole, Single-Throw) | Set Point: -1.65" W.C. | 1.81" W.C. rated | Normally Open | Includes factory mounting bracket | Manufactured by Honeywell for Carrier
  • OEM vs Generic: This is the genuine OEM part with the factory-calibrated diaphragm set point. Aftermarket switches frequently ship with loose W.C. tolerances that cause nuisance lockouts or, worse, allow ignition under unsafe draft conditions.
  • Install difficulty: 2/5 — Power down the furnace at the breaker before beginning. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers. Photograph all hose and wiring connections before removal. Note port orientation (+/−) when routing the pressure hose to the new switch. Discharge any residual pressure from the inducer housing before disconnecting hoses.
  • Warranty: 1-year OEM manufacturer warranty against defects. Supersedes obsolete part numbers HK06NB119, HK06NB120, HK06NB122, and HK06NB123. Ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PG9MAB024060ABSA and compatible across 200+ Carrier and Bryant residential furnace models. Always verify your unit's existing W.C. rating on the data plate or original switch label before ordering. Our technical team is available to confirm fitment before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG9MAB024060ABSA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG9MAB024060ABSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG9MAB024060ABSA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.