This OEM pressure switch (part# HK06NB124) is the factory-specified replacement for the Carrier PG9MAB024040ABSA gas furnace. The pressure switch proves that the inducer motor has created adequate negative pressure before allowing the ignition sequence to proceed — a critical safety interlock in every 90%+ efficiency furnace. When this switch fails or its diaphragm stiffens, the control board cannot confirm proper draft and will lock out ignition, typically logging an error code 31 (pressure switch stuck open). The result: a furnace that attempts to start, fails, and shuts down before any heat is produced.
Compatibility: Designed for the Carrier PG9MAB024040ABSA gas furnace. This part covers over 200 Carrier and Bryant residential furnace models — always verify the 1.81" W.C. rating against your unit's data plate or existing switch label before ordering. Our team is available to confirm fitment prior to purchase. Order today and receive same-day shipping on all in-stock OEM parts.