OEM Carrier Pressure Switch w/ Bracket 1.81
Carrier

OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB024040ABSA

SKU: CARRIE-PG9MAB024040ABSA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAB024040ABSA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket 1.81" WC SPST for Model PG9MAB024040ABSA

This OEM pressure switch (part# HK06NB124) is the factory-specified replacement for the Carrier PG9MAB024040ABSA gas furnace. The pressure switch proves that the inducer motor has created adequate negative pressure before allowing the ignition sequence to proceed — a critical safety interlock in every 90%+ efficiency furnace. When this switch fails or its diaphragm stiffens, the control board cannot confirm proper draft and will lock out ignition, typically logging an error code 31 (pressure switch stuck open). The result: a furnace that attempts to start, fails, and shuts down before any heat is produced.

  • Specs: 1.81" W.C. (inches water column) | SPST (Single-Pole, Single-Throw) | 1/4" barb hose connection | Includes factory mounting bracket | Rated for residential gas furnace application
  • OEM vs Generic: This is the genuine Carrier OEM part — factory-calibrated to the exact 1.81" W.C. set point required by your PG9MAB024040ABSA. Generic aftermarket switches often carry ±5–10% tolerance variance, which can cause nuisance lockouts or, worse, allow operation under unsafe draft conditions.
  • Install Difficulty: 2/5 — A straightforward swap accessible to experienced DIYers. Tools needed: 1/4" nut driver, flat-head screwdriver, and a phone camera to document hose routing before disconnecting. Power down and gas-off the furnace before beginning. Note port orientation when transferring hoses from the old switch to the new bracket.
  • Supersedes: HK06NB124 is the current consolidated replacement for obsolete part numbers HK06NB119, HK06NB120, and HK06NB122. Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG9MAB024040ABSA gas furnace. This part covers over 200 Carrier and Bryant residential furnace models — always verify the 1.81" W.C. rating against your unit's data plate or existing switch label before ordering. Our team is available to confirm fitment prior to purchase. Order today and receive same-day shipping on all in-stock OEM parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB024040ABSA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB024040ABSA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAB024040ABSA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.