Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Single Run Capacitor 3 MFD 250V for PG9MAA060140AFKA
OEM Carrier Single Run Capacitor 3 MFD 250V for PG9MAA060140AFKA
OEM Carrier Single Run Capacitor 3 MFD 250V for PG9MAA060140AFKA
OEM Carrier Single Run Capacitor 3 MFD 250V for PG9MAA060140AFKA
Carrier

OEM Carrier Single Run Capacitor 3 MFD 250V for PG9MAA060140AFKA

SKU: CARRIE-PG9MAA060140AFKA-CAPACITOR-HC91PD001 Brand: Carrier
Guaranteed to fit PG9MAA060140AFKA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single Run Capacitor 3 MFD 250V for Model PG9MAA060140AFKA

This is the genuine OEM Carrier single run capacitor (part number HC91PD001), factory-specified for the Carrier PG9MAA060140AFKA gas furnace. The run capacitor supplies and sustains the electrical charge required to keep the draft inducer blower motor running through every heating cycle. When this capacitor weakens or fails, you may notice the inducer motor struggling to start, running loudly, overheating and tripping the high-limit switch, or failing to run altogether — resulting in a no-heat lockout condition.

  • Specs: 3 MFD (microfarad) | 250V AC | Rectangular/square case | ±5% tolerance | 50/60 Hz | Manufactured by ASC Capacitors (cross-reference: CMKS-X345)
  • OEM vs Generic: This OEM Carrier capacitor is built to exact factory tolerance (±5%), ensuring proper motor run current and protecting inducer motor windings from premature wear. Off-brand replacements often exceed ±10% tolerance, leading to motor overheating and shortened component life.
  • Install difficulty: 2/5 — Discharge the capacitor before handling any terminals. Tools needed: 1/4" nut driver, needle-nose pliers, multimeter (capacitance setting). Always photograph existing wiring before disconnecting leads. Turn off power at the breaker before beginning.
  • Warranty: 1-year OEM manufacturer warranty against defects. Orders ship same business day from our warehouse when placed before cutoff.

Compatibility: Direct OEM replacement for Carrier model PG9MAA060140AFKA gas furnace draft inducer motor circuit. Also fits a wide range of Carrier, Bryant, and Payne furnace and air handler models that specify the HC91PD001. Always verify MFD rating, voltage, and physical form factor against your unit's data plate before ordering. Have a fitment question? Our HVAC parts specialists verify compatibility before you buy — reach out before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Carrier PG9MAA060140AFKA?
Yes. This is the factory-specified OEM capacitor for the Carrier PG9MAA060140AFKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Carrier PG9MAA060140AFKA?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.