OEM Carrier Furnace Transformer 120V–24V 40VA for Model PG9MAA060120AFKA

This OEM Carrier control transformer is the factory-specified replacement for the Carrier PG9MAA060120AFKA gas furnace. It steps down 120V line voltage to the 24V AC signal that powers every low-voltage control circuit in your system — including the thermostat, control board, gas valve, and inducer relay. When this transformer fails, the entire low-voltage side of your furnace goes dark: the thermostat goes blank, nothing responds to a heat call, and the system won't attempt ignition at all.

  • Specs: Input 120V AC | Output 24V AC | 40VA rated | 60Hz | Foot-mount configuration | Wire-lead connection | Integrated 3A fuse protection | Replaces OEM part number HT01BC116 (superseded by HT680054)
  • OEM vs Generic: OEM transformers are wound to exact factory VA tolerances, ensuring stable 24V output under full control-circuit load. Undersized or off-tolerance generic units can cause erratic board behavior, nuisance lockouts, or premature control board failure — one reviewer noted a generic unit would not mount correctly without modification.
  • Install Difficulty: 2/5 — Always shut off power at the disconnect and breaker before servicing. Photograph all wiring connections before removing the old transformer. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, multimeter (verify 24V output after install). Check R-to-C terminals on the control board to confirm proper voltage.
  • Warranty: 1-year OEM factory warranty. Stocked in our warehouse and ships the same business day your order is placed.

Compatibility: Designed for the Carrier PG9MAA060120AFKA gas furnace. Note that OEM part number HT01BC116 has been superseded — this listing ships the current authorized replacement. Verify your existing transformer's input/output voltage and VA rating against your unit's data plate before ordering. Our fitment team is available to confirm compatibility before you buy — don't hesitate to reach out.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA060120AFKA?
Yes. This is the factory-specified OEM transformer for the Carrier OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA060120AFKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA060120AFKA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.