Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAA060120AEKA
Carrier

OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAA060120AEKA

SKU: CARRIE-PG9MAA060120AEKA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAA060120AEKA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket HK06NB124 for Model PG9MAA060120AEKA

This is the genuine OEM replacement pressure switch with mounting bracket for the Carrier PG9MAA060120AEKA gas furnace. The pressure switch is a safety device that proves the inducer (draft) motor is running and creating adequate negative pressure before allowing the ignition sequence to proceed. When this switch fails or becomes stuck open, the furnace control board will halt the startup cycle — typically logging an error code — and you'll have no heat. Common symptoms include the inducer motor spinning normally but the furnace locking out before spark or gas valve activation.

  • Specs: -1.65" W.C. set point | SPST (Single-Pole, Single-Throw) | Includes factory mounting bracket | Supersedes HK06NB119, HK06NB120, and HK06NB122
  • OEM vs Generic: This OEM part is precision-calibrated to the exact W.C. rating required by your Carrier furnace control board. Generic switches frequently carry ±10–15% W.C. tolerances, which can cause nuisance trips or fail to protect against a true blocked flue — a potential safety hazard.
  • Install difficulty: 2/5 — Turn off gas and 120V power before beginning. Tools needed: 1/4" nut driver, flat-head screwdriver, needle-nose pliers. Label and photograph hose connections before removal. Replace any deteriorated rubber hose tubing at the same time to prevent a callback.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.

Compatibility: Direct factory-specified replacement for Carrier model PG9MAA060120AEKA. This switch is also used across more than 200 Carrier and Bryant residential furnaces — always verify the W.C. rating on your existing switch or unit data plate before ordering. Our parts specialists are available to confirm fitment before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAA060120AEKA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAA060120AEKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket HK06NB124 — PG9MAA060120AEKA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera