Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA048060AFKA
Carrier

OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA048060AFKA

SKU: CARRIE-PG9MAA048060AFKA-TRANSFORMER-HT01BC116 Brand: Carrier
Guaranteed to fit PG9MAA048060AFKA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Control Transformer 120V–24V 40VA for Model PG9MAA048060AFKA

This OEM step-down control transformer is the factory-specified replacement for the Carrier PG9MAA048060AFKA gas furnace. The transformer converts 120V line voltage to 24V AC, powering the entire low-voltage control circuit — including the thermostat, gas valve, inducer relay, and ignition board. When this transformer fails, the furnace goes completely dead: the thermostat loses power, no call for heat is processed, and the system will not attempt ignition. A failed transformer is often misdiagnosed as a board or thermostat fault, making correct identification critical before replacing more expensive components.

  • Specs: Primary voltage: 120 VAC | Secondary voltage: 24 VAC | VA rating: 40VA | Frequency: 50/60 Hz | Phase: Single | Replaces OEM part number HT01BC116 (superseded by HT680054)
  • OEM vs Generic: OEM transformers are wound to exact factory VA and voltage tolerances, protecting sensitive control boards from under- or over-voltage conditions. Generic units often lack built-in overcurrent protection and can fail prematurely under normal cycling loads.
  • Install difficulty: 2/5 — Shut off furnace power at the disconnect and breaker before starting. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Label and photograph all low-voltage wiring before disconnecting. Verify 24V output at secondary terminals with a multimeter before reassembly.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.

Compatibility: Fits Carrier model PG9MAA048060AFKA gas furnace. This part supersedes OEM part number HT01BC116. Always verify your unit's data plate voltage and VA specifications before ordering. Our parts specialists are available to confirm fitment — order with confidence.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA048060AFKA?
Yes. This is the factory-specified OEM transformer for the Carrier OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA048060AFKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier OEM Carrier Furnace Transformer 120V-24V 40VA — PG9MAA048060AFKA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.