Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket 1.65
Carrier

OEM Carrier Pressure Switch w/ Bracket 1.65" WC — PG9MAA048060AEKA

SKU: CARRIE-PG9MAA048060AEKA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAA048060AEKA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket -1.65" WC for Model PG9MAA048060AEKA

This OEM pressure switch with mounting bracket (part# HK06NB124) is the factory-specified replacement for the Carrier PG9MAA048060AEKA gas furnace. The pressure switch proves that the induced draft blower has established proper airflow before allowing the ignition sequence to proceed. When it fails — or when the diaphragm stiffens or the hose cracks — the furnace control board detects an open switch circuit and locks out before any ignition attempt, often displaying a fault code. The result: no heat, a flashing LED error code, and a cold home.

  • Specs: -1.65" W.C. (inches water column) set point | SPST (single-pole, single-throw) | Includes factory mounting bracket | Replaces obsolete part numbers HK06NB119, HK06NB120, and HK06NB122
  • OEM vs Generic: This is the genuine Carrier OEM part, factory-calibrated to the exact -1.65" WC trip point required by the PG9MAA048060AEKA's inducer assembly. Aftermarket pressure switches often carry wider trip-point tolerances that can cause nuisance lockouts or, worse, allow marginal combustion airflow — both of which the OEM part is engineered to prevent.
  • Install difficulty: 2/5 — A straightforward swap for anyone comfortable working inside a furnace cabinet. Tools needed: 1/4" nut driver, flat-head screwdriver, and a smartphone camera. Always photograph the existing hose routing and wiring before disconnecting anything. Power off and allow the inducer to cool before beginning. The included bracket simplifies direct bolt-in replacement.
  • Warranty: 1-year OEM factory warranty. In-stock and ships the same business day from our warehouse.

Compatibility: Designed for the Carrier PG9MAA048060AEKA packaged gas furnace. This switch is also used across more than 200 Carrier and Bryant residential furnaces — always verify your existing switch's W.C. rating on the data label before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before your order ships.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket 1.65" WC — PG9MAA048060AEKA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket 1.65" WC — PG9MAA048060AEKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket 1.65" WC — PG9MAA048060AEKA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.