Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket 1.81
Carrier

OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA036080AEKA

SKU: CARRIE-PG9MAA036080AEKA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAA036080AEKA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket 1.81" WC for Model PG9MAA036080AEKA

This OEM pressure switch with mounting bracket (part HK06NB124) is the factory-authorized replacement for the Carrier PG9MAA036080AEKA gas furnace. The pressure switch is a safety device that monitors negative pressure created by the inducer draft motor. Before each ignition sequence, the furnace control board checks this switch to confirm the inducer is operating correctly and the flue path is unobstructed. When the switch fails — or the diaphragm stiffens with age — the board will not advance to ignition, leaving you with a no-heat lockout, typically accompanied by a fault code indicating a pressure switch or inducer circuit problem.

  • Specs: 1.81" W.C. set point | SPST (Single-Pole, Single-Throw) | Normally Open | Includes factory mounting bracket | Honeywell-manufactured OEM component
  • OEM vs Generic: This is a factory-spec Carrier OEM part with precisely calibrated diaphragm sensitivity. Aftermarket switches can carry wider W.C. tolerances, causing nuisance lockouts or — worse — failing to detect a blocked flue, creating a safety hazard. OEM is strongly recommended for pressure switches.
  • Install difficulty: 2/5 — Power down and lock out the furnace before beginning. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, flathead screwdriver. Photograph hose routing before disconnecting. Note port labeling (+/−) and match the restrictor orifice port to the original configuration before reconnecting hoses.
  • Warranty & Shipping: 1-year OEM manufacturer warranty against defects. In stock — ships same business day from our warehouse.

Compatibility & Supersession: Designed as the direct OEM replacement for Carrier PG9MAA036080AEKA gas furnaces. Part HK06NB124 also supersedes obsolete part numbers HK06NB119, HK06NB120, and HK06NB122. Always verify your unit's data plate and existing switch W.C. rating before ordering. Our parts team is standing by to confirm fitment — contact us before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA036080AEKA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA036080AEKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA036080AEKA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.