Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Transformer 120V–24V 40VA for PG9MAA024060AFKA
Carrier

OEM Carrier Furnace Transformer 120V–24V 40VA for PG9MAA024060AFKA

SKU: CARRIE-PG9MAA024060AFKA-TRANSFORMER-HT01BC116 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Furnace Transformer 120V–24V 40VA for Model PG9MAA024060AFKA

This OEM step-down transformer (part # HT01BC116 / superseded by HT680054) is the factory-specified control circuit transformer for the Carrier PG9MAA024060AFKA gas furnace. Its job is to convert 120V line voltage down to the 24V AC signal that powers your thermostat, gas valve, inducer relay, and control board logic. When this transformer fails — whether from a shorted secondary, a blown internal fuse, or heat-related winding failure — the entire low-voltage control circuit goes dead: the furnace will not respond to the thermostat, will not attempt ignition, and may show no LED activity on the control board whatsoever.

  • Specs: Primary input 120V AC | Secondary output 24V AC | VA rating: 40VA | Frequency: 60Hz | Mounting: Foot-mount | Connection: Wire leads with insulated female connectors | Includes 3A inline fuse
  • OEM vs Generic: OEM transformers are wound to exact VA tolerance, ensuring stable 24V output under full control-circuit load. Generic units often under-deliver VA capacity, causing erratic relay chatter, nuisance lockouts, and premature contactor wear.
  • Install difficulty: 2/5 — Shut off furnace power at the disconnect before starting. Photograph or label all wiring connections before removal. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always verify 0V at transformer terminals before touching wires.
  • Warranty: 1-year OEM factory warranty. In stock — ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PG9MAA024060AFKA gas furnace. Note: OEM part HT01BC116 has been superseded by Carrier part # HT680054 — this listing ships the current OEM equivalent. Verify your unit's data plate shows a 120V primary / 24V secondary / 40VA transformer before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier PG9MAA024060AFKA?
Yes. This is the factory-specified OEM transformer for the Carrier PG9MAA024060AFKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier PG9MAA024060AFKA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online